焱色
返回 蒸汽工程

ZQ-NS Series Condensate Closed-Loop Recovery Unit

Closed-loop recovery of steam condensate to the boiler room, with recovered water temperature ≥120°C, saving over 20% in fuel. Equipped with automatic level control, anti-cavitation pump set, and stainless steel water tank, widely used in the severe cold regions of Northeast China, effectively solving issues such as high heat loss in open-loop recovery and winter freezing.

ZQ-NS Series Condensate Closed-Loop Recovery Unit
Steam Engineering8个特性

产品特性

Closed-loop system, heat loss <5%Recovered water temperature ≥120°CAnti-cavitation centrifugal pump set304 stainless steel collection tankPLC automatic level controlRecovery cost per ton of condensate <2 RMBInsulation and anti-freeze design for severe cold regionsRecovery rate 85%-95%

产品描述

ZQ-NS Series Condensate Closed-Loop Recovery Unit

After releasing latent heat in steam-consuming equipment, steam condenses into high-temperature water (120-160°C), containing 20%-25% of the total steam heat. ZQ-NS adopts a fully enclosed design, directly delivering high-temperature condensate back to the boiler room, achieving dual recovery of heat and water resources.

Process Flow

  1. Condensate from each steam consumption point → collection tank → dirt filter → high-temperature condensate pump → boiler room
  2. Collection tank equipped with automatic air vent valve
  3. Fully closed-loop operation, no contact with atmosphere, eliminating secondary oxygen dissolution

Selection Parameters

ModelRecovery CapacityHeadPowerTank VolumeApplicable System
ZQ-NS1001-3t/h30m2.2kW1.0m³2-4t/h Boiler
ZQ-NS2003-6t/h30m4.0kW2.0m³4-8t/h Boiler
ZQ-NS3006-12t/h35m7.5kW3.0m³8-15t/h Boiler

Northeast case study: After a pharmaceutical factory in Harbin installed the ZQ-NS300, the condensate recovery rate increased from 62% to 91%, saving over 280,000 RMB in annual steam costs.