焱色
返回 蒸汽工程

ZQ-FG Series Steam Distribution Header (DN200-DN800)

Core equipment for boiler room steam distribution, featuring multiple independent outlets, each equipped with a stop valve and pressure gauge, ensuring no interference between steam consumers. Suitable for central heating stations in severe cold regions of Northeast China, food processing, pharmaceutical and chemical industries, supporting both overhead and trench installation.

ZQ-FG Series Steam Distribution Header (DN200-DN800)
Steam Engineering8个特性

产品特性

DN200-DN800 multiple specifications available2-12 independent steam outletsDesign pressure 0.7-2.5MPaEach outlet equipped with stop valve + pressure gaugeDrain and blowdown port at the bottomRock wool insulation layer (thickened for severe cold regions)Carbon steel/Q345R materialInspection certificate issued by Special Equipment Inspection Institute

产品描述

ZQ-FG Series Steam Distribution Header

The steam distribution header is the core equipment of the boiler room steam distribution system, distributing steam generated by the boiler to each steam branch as required. It is designed and manufactured strictly in accordance with the GB150 "Pressure Vessels" standard, suitable for severe cold regions of Northeast China and various industrial steam pipeline networks.

Product Features

  • Cylinder body made of Q345R low-alloy steel plate rolled and formed, with 100% non-destructive testing on welds
  • Each steam outlet pipe is equipped with an independent stop valve and pressure gauge, with no interference between branches
  • Drain valve interface and blowdown port provided at the bottom
  • Insulation layer uses rock wool + aluminum skin outer shell, with customizable thickening available for severe cold regions

Technical Parameters

ModelCylinder DiameterNumber of OutletsDesign PressureDesign TemperatureApplicable Boiler
ZQ-FG200DN2002-4 outlets1.0MPa184℃0.5-1t/h
ZQ-FG300DN3003-6 outlets1.0-1.6MPa204℃1-3t/h
ZQ-FG400DN4004-8 outlets1.6MPa204℃3-6t/h
ZQ-FG500DN5006-10 outlets1.6-2.5MPa226℃6-10t/h
ZQ-FG800DN8008-12 outlets2.5MPa226℃10-20t/h

Application scenarios: Central heating exchange stations in Harbin and Northeast China, food steaming and cooking production lines, pharmaceutical sterilization workshops, chemical reactor steam supply, etc.